Filtriseade Blower


Blower and Jet filters
The blower and Jet filter is an under- and over-pressure filter, designed for continuous operation.Constructed as a self-supporting sheet metal construction. The round design ensures great strength combined with low weight.

Surface
Powder coated to corrosion class C3 cf. ISO 12944.

Inlet
The Blower and Jet filters are fitted with 180º tangential inlets to ensure effective sorting of heavy materials before the process air passes through the filter medium.
Blower and Jet filters are also available with total separators. Standard height is 1000 mm, with the inlet at 90ºC. This type of inlet is used in plants in which the process air contains heavy and sharp articles to prevent them coming into contact with the filter medium.

Cleaning system
BF-36, 60 and 84/90-ET filters are available with PowerPulse® or Blower cleaning. JF-9 and JF-18-filters are supplied with Jet or Blower cleaning.

Discharge system
Conical or scraper bottoms are available for the discharge system, but silo filter is also available.

ATEX
BF-36, 60 and 84/90-ET with PowerPulse® cleaning and external compressed air have approved explosion membranes. Choose between side venting or JKF’s specially developed VFV® explosion relief venting, which vents explosion pressure vertically through the filter top. The filters fulfil pressure shock-resistance according to VDI 2263. Venting according to VDI 3673. The Jet filter with external compressed air source is supplied ATEX-approved.

Operating range
Pressure: +/- 5000 Pa (available up to +20 kPa to -10 kPa)
Filter area: 6.5-200 m²
Max. operating temperature: 70ºC
Min. operating temperature: -20ºC (available for: -40 ºC)

Connection
Gear motor Blower/Jet cleaning:
Type 9, 18 and 36: 0.25 kW, 20 min-1, 3 x 400 V, 50 Hz, 1.1 A
Type 60, 84 and 90: 0.25 kW, 6.3 min-1, 3 x 400 V, 50 Hz, 0.82 A

Cleaning fan
Type 9 and 18: 3.0 kW, 2,865 min-1, 3 x 400 V, 50 Hz, 6.15 A
Type 36: 5.5 kW, 2860 min-1, 3 x 400 V, 50 Hz, 11 A
Type 60: 7.5 kW, 2880 min-1, 3 x 400 V, 50 Hz, 14.5 A
Type 84 and 90: 11.0 kW, 2900 min-1, 3 x 400 V, 50 Hz, 20 A

Inductive sensor, Blower/Jet cleaning:
24 VDC

Gear motor PowerPulse® cleaning system:
0.12 kW, 15.6 min-1, 3 x 230 V, 50 Hz, 0.7 A

Gear motor scraper bottom:
Type 9, 18 and 36: 0.55 kW, 11.0 min-1, 3 x 400 V, 50 Hz, 1.7 A
Type 60, 84 and 90: 0.75 kW, 11.0 min-1, 3 x 400 V, 50 Hz, 2.2 A

Inductive sensor, scraper bottom:
24 VDC

PowerPulse-® ECOTROL® filter control system, BF-CT-ET:
0.6 kW, 1 x 230 V, 50 Hz, 1.9 A

External compressed air - PowerPulse®:
5 bar, min. 350 Nl/min.
Air quality according to ISO 8573-1: Quality class (5. 4. 4)
External connection: ¼” internal thread.

Internal compressor - PowerPulse®:
2.2 kW, 3 x 400 V, 50 Hz, 5.9 A
Capacity: 350 Nl/min.

Noise
Noise level during cleaning measured 5 m above the ground:
Jet: 73.6 dBA
PowerPulse®: 70.4 dBA
Blower: 78.8 dBA

Accessories
Ladder/gangway:
Ladder/gangway designed according to ISO/EN/DIN 14122.3/4 and available in several configurations.
Ladder with gangway, front-mounted
Ladder with double gangway, front-mounted
Monitoring equipment for explosion membrane

Door contacts:
2.3 (close-before-switch-contact) in accordance with EN50047, IP67 NC contact.

Kontakt

Tallinn - Peterburi tee 46-303
Tel.: 613 9747
E-post: tallinn@cliox.ee

Tartu - Tähe 131C
Tel.: 736 6460
E-post: tartu@cliox.ee

Theme by Danetsoft and Danang Probo Sayekti inspired by Maksimer